NT95L, 16-50A, Latching Relay
♦ Current: 50A,16A
♦ Contact form: 1A
♦ Coil: DC3-48v
Model NT95L
Size 39mm×15mm×25mm
Coil Single coil
double coils
Coil rated voltage DC:3V,6V,9V,12V,24V,48V
Max. Switching Power 440VA
Max. Switching Voltage 30VDC 227V
Polarity standard
reverse polarity
Enclosure Sealed type
Dust cover
Operation life Electrical 1×100,000 times
Mechanical 1×1000,000 times
NT95L, 16-50A, Latching Relay
Features
• Single and double coils magnet latching relay available.
• Switching capacity up to 50A. • PC board mounting |
Ordering Information
NT95L A D Z R DC12V 1 2 3 4 5 6 |
|
1. Part number | NT95L |
2. Contact arrangement | A:1A |
3 Coil | Nil:Single coil; D:double coils; |
4. Enclosure | S: Sealed type z: Dust cover |
5 Polarity: | Nil: standard; R: reverse polarity; |
6. Coil rated voltage(V) | DC:3,6,9,12,24,48 |
Contact Data
Contact Arrangement | 1A(SPSTNO) | |
Contact Materials | AgSnO2 | |
Contact Rating | resistive: 50A/277VAC; motor load:5HP 240VAC; Inductive: incandescent lamp 5000W 240VAC; 16A/277VAC |
|
Max. Switching Power | 440VA | |
Max. Switching Voltage | 30VDC 227V Max. Switching Current: 50A | |
Contact Resistance & Voltage drop | ≤20mΩ Item 4.12 of IEC 61810-7 | |
Operation life | Electrical | 1×100,000 times Item 4.12 of IEC 61810-7 |
Mechanical | 1×1000,000 times Item 4.12 of IEC 61810-7 |
CAUTION: 1.For the intermediate current, it only applies to the room temperature.
Coil Parameter
Dash numbers |
Coil rated voltage VDC |
Coil resistance ±Ω10% |
Switching voltage VDC(80% of rated voltage ) |
Pulse magnitude ms |
Coil power consumption W |
Operate Time ms |
Release Time ms |
1 Coil | |||||||
006-1500 009-1500 012-1500 024-1500 048-1500 |
6 9 12 24 48 |
24 54 96 384 1536 |
4.8 7.2 9.6 19.2 38.4 |
≥50 | 1.5 | ≤15 | ≤15 |
2 Coil | |||||||
006-3000 009-3000 012-3000 024-3000 048-3000 |
6 9 12 24 48 |
12+12 27+27 48+48 192+192 768+768 |
4.8 7.2 9.6 19.2 38.4 |
≥50 | 2×3.0 | ≤15 | ≤15 |
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Operation condition
Insulation Resistance | 100MΩ min. (500VDC) | Item 7 of IEC 60255-5 |
Dielectric Strength Between contacts Between contact and coil |
50Hz 1000V 50Hz 2500V |
Item 6 of IEC 60255-5 Item 6 of IEC 60255-5 |
Shock Resistance | 100m/s² 11ms | IEC 68-2-27 test Ea |
Vibration Resistance | 10Hz~55Hz double amplitude 1.5mm | IEC 68-2-6 test Fc |
Terminals strength | 10N | IEC 68-2-21 test Ua 1 |
Solderability | 235°C±2°C 3s±0.5s | IEC 68-2-20 Test Ta method 1 |
Ambient Temperature | -40°C ~70°C | |
Relative Humidity | 95% (at35°C) | IEC 68-2-3 test Ca |
Mass | 6g |
Safety approvals
Safety approval | UL&CUR | TÜ V | CQC |
Load | 6A/120VAC;10A/125VAC 5A/240VAC,250VAC 4.2A/277VAC TV-5 1/4HP/277VAC 250VAC 240VAC 120VAC |
5A/250VAC 28VDC |
5A/250VAC |