NT90L, 5-50A, Latching Relay
♦ Current: 5A,16A,30A,40A,50A
♦ Contact Form: 1A,1B,1C
♦ Coil(V): DC 5,12,24,48
Model NT90L
Contact arrangement SPST SPDT
Size 32.5mm×27.6mm×20.5mm
Enclosure Sealed type
Covered
Open
Coil rated voltage DC5V,12V,24V,48V
Coil Singal coil
Double coils
Max. Switching Voltage 110VDC 300VAC
Max. Swit ching Current 50A
Operation life Electrical See contact rating
Mechanical 100,000 times
Application Office equipment relay
Teaching audition equipment relay
Armamentarium relay
Measuring instrument relay
Emulator relay
Safety alarm relay
NT90L, 5-50A, Latching Relay
Feature
1. Single and double coils magnet latching relay available.
2. Switching capacity up to 50A. 3. Energy saving and enviromental friendly product. |
Ordering information
NT90L 30 A S DC12V 0.9 D 1 2 3 4 5 6 7 |
|
1. Part number | NT90L |
2. Load | 30A,40A,50A/277VAC,28VDC (Resistive load) 5000W 240VAC (Incandescent Lamp ) 5A/280VAC; 16A/280VAC(50A) (Electronicballast) 2HP 250VAC(50A)(Motor load) |
3. Contact arrangement | A: 1A; B:1B C:1C; |
4. Enclosure | S: Sealed type E: Covered N:Open |
5. Coil power consumption | 09:0.9W; 1.5:1.5W; |
6. Coil rated voltage(V). | 5,12,24,48 |
7: Coil | NIL:Singal coil; D:Double coils |
Contact Data
Contact Arrangement | 1A (SPSTNO); 1B(SPSTNC); 1C(SPDT(B~M)); | |
Contact Material | AgSnO2 | |
Contact Rating (resistive) | 30A.40A/277VAC.28VDC 3×10,000; 50A/277VAC 5×10,000 OPS (Resistive load); 5000W 240VAC 3×10,000 OPS; (Incandescent Lamp ), 5A/280VAC 6000OPS (Electronicballast); 2HP 250VAC 2×10,000 OPS; 5HP 277VAC 3×10,000 OPS;(Motor load) |
|
Max. Switching Power | 1200W 12000VA ;1500w 12500VA Min. Switching load 0.01mA/10mV Reference Value | |
Max. Switching Voltage | 110VDC 300VAC Max. Swit ching Curr ent:50A | |
Contact Resistance or Voltage drop |
≤20mΩ Item 4.12 of IEC 61810-7 | |
Operation life | Electrical | See contact rating Item 4.30 of IEC 61810-7 |
Mechanical | 100,000 Item 4.31 of IEC 61810-7 |
CAUTION:
Relays previously tested or used above 10mA resistive at 6V maximum DC or peak AC open circuit are not recommended for subsequent
use in low level applications.
Coil Parameter
Dash numbers | Rated voltage VDC |
Coil resistance Ω±10% | Switching voltage VDC (80%of rated voltage ) |
Operated voltage ramge VDC |
Plus magnitude ms |
Coil power |
Operate Time ms | Reset Time ms |
Single Coil Parameter | ||||||||
005-900 012-900 024-900 048-900 |
5 12 24 48 |
28 160 640 2560 |
4.0 9.6 19.2 38.4 |
5-6 12-14.4 24-28.8 48-57.6 |
≤100 | 0.9W | ≤15 | ≤15 |
Double Coil Parameter | ||||||||
005-1500 012-1500 024-1500 048-1500 |
5 12 24 48 |
17 96 384 1536 |
4.0 9.6 19.2 38.4 |
5∼6 12∼14.4 24∼28.8 48∼57.6 |
≤100 | 1.5W | ≤15 | ≤15 |
CAUTION:
I. Wtien tatding relays are instailed in equipment, tha latch and reset coil shoud net be powered simullaneously. Coil shoiid not be
pulse wfth Iess than tha nommai coil voftage and pulse width shodd be a minimum df three times, the specified operate time of the
relay. If these condition are not followed, it is possible for the relay to in be the magneticdlyneutral position .
2. Swftdwg voftage is for test purpose only and are no to to used design criteria.
Operation conditio
Insulation Resistance | 1000MΩ at(500VDC) | Item 7 of IEC 60255-5 |
Dielectric Strength BetweenContacts Between Contact Poles |
50 Hz 1500V 1min 50Hz 2500 V 4000V1 min |
Item 6 of IEC 60255-5 Item 6 of IEC 60255-5 |
Shock resistance | 500m/s² 11ms; | IEC 68-2-27 Test Ea |
Vibration resistance | 10Hz~55Hz Double amplitude 1.5mm | IEC 68-2-6 Test Fc |
Terminals strength | 10N | IEC 68-2-21 Test Ua1 |
Solderability | 235°C±2°C 3s°C±0.5s°C | IEC 68-2-20 Test Ta method 1 |
Temperature Range | -40°C ∼85°C | |
Relative Humidity | 85%(at 40°C) | IEC 68-2-3 Test Ca |
Mass | Approx. 1.5g |
Safety approvals
Safety approval | UL&CUR | CQC |
Load | 30A,40A/277VDC, | 30A,40A/277VDC, |