NT90L, 5-50A, Latching Relay

♦ Current: 5A,16A,30A,40A,50A

♦ Contact Form: 1A,1B,1C

♦ Coil(V): DC 5,12,24,48

 

 

Model NT90L
Contact arrangement SPST   SPDT
Size 32.5mm×27.6mm×20.5mm

Enclosure  Sealed type              
Covered
Open
Coil rated voltage  DC5V,12V,24V,48V
Coil  Singal coil                       
 Double coils
Max. Switching Voltage   110VDC     300VAC     
Max. Swit ching Current 50A
Operation life Electrical See contact rating   
Mechanical   100,000 times 
Application                 Office equipment relay
Teaching audition equipment relay 
Armamentarium relay
Measuring instrument relay
Emulator relay
Safety alarm relay 

 

Product Detail

 

NT90L, 5-50A, Latching Relay

 

Feature

1. Single and double coils magnet latching relay available.

2. Switching capacity up to 50A.

3. Energy saving and enviromental friendly product.

 

Ordering information

NT90L         30      A        S       DC12V         0.9            D
    1               2       3         4           5                6              7
1.  Part number  NT90L 
2. Load 30A,40A,50A/277VAC,28VDC (Resistive load)
5000W 240VAC (Incandescent Lamp )
5A/280VAC;
16A/280VAC(50A) (Electronicballast)
2HP 250VAC(50A)(Motor load)
3. Contact arrangement A: 1A;    B:1B    C:1C;
4. Enclosure S: Sealed type        E: Covered         N:Open
5. Coil power consumption 09:0.9W;     1.5:1.5W;
6. Coil rated voltage(V).  5,12,24,48
7: Coil  NIL:Singal coil;            D:Double coils

 

Contact Data

Contact Arrangement 1A (SPSTNO);      1B(SPSTNC);     1C(SPDT(B~M));
Contact Material AgSnO2
Contact Rating (resistive) 30A.40A/277VAC.28VDC 3×10,000;
50A/277VAC 5×10,000 OPS (Resistive load);
5000W 240VAC 3×10,000 OPS;
(Incandescent Lamp ), 5A/280VAC 6000OPS (Electronicballast);
2HP 250VAC 2×10,000 OPS;
5HP 277VAC 3×10,000 OPS;(Motor load)
Max. Switching Power 1200W 12000VA ;1500w 12500VA                   Min. Switching load 0.01mA/10mV                                                                                    Reference Value
Max. Switching Voltage 110VDC 300VAC                                               Max. Swit ching Curr ent:50A
Contact Resistance or
Voltage drop
≤20mΩ                                                               Item 4.12 of IEC 61810-7
Operation life Electrical See contact rating                                              Item 4.30 of IEC 61810-7
Mechanical 100,000                                                              Item 4.31 of IEC 61810-7

CAUTION:
Relays previously tested or used above 10mA resistive at 6V maximum DC or peak AC open circuit are not recommended for subsequent

use in low level applications.

 

Coil Parameter

Dash numbers Rated voltage
VDC 
Coil resistance Ω±10% Switching
voltage VDC
(80%of rated
voltage )
Operated
voltage
ramge
VDC
Plus
magnitude
ms
Coil
power
Operate Time ms Reset Time
ms
Single Coil Parameter
005-900
012-900
024-900
048-900
5
12
24
48
28
160
640
2560
4.0
9.6
19.2
38.4
5-6
12-14.4
24-28.8
48-57.6
≤100 0.9W ≤15 ≤15
Double Coil Parameter
005-1500 
012-1500
024-1500
048-1500
5
12
24
48
17
96
384
1536
4.0
9.6
19.2
38.4
5∼6
12∼14.4
24∼28.8
48∼57.6
≤100 1.5W ≤15 ≤15

CAUTION:
I. Wtien tatding relays are instailed in equipment, tha latch and reset coil shoud net be powered simullaneously. Coil shoiid not be
pulse wfth Iess than tha nommai coil voftage and pulse width shodd be a minimum df three times, the specified operate time of the
relay. If these condition are not followed, it is possible for the relay to in be the magneticdlyneutral position .
2. Swftdwg voftage is for test purpose only and are no to to used design criteria.

 

Operation conditio

Insulation Resistance 1000MΩ at(500VDC) Item 7 of IEC 60255-5
Dielectric Strength
BetweenContacts
Between Contact Poles
50 Hz 1500V 1min
50Hz 2500 V 4000V1 min
Item 6 of IEC 60255-5
Item 6 of IEC 60255-5
Shock resistance 500m/s² 11ms; IEC 68-2-27 Test Ea
Vibration resistance 10Hz~55Hz Double amplitude 1.5mm IEC 68-2-6 Test Fc
Terminals strength 10N IEC 68-2-21 Test Ua1
Solderability 235°C±2°C    3s°C±0.5s°C IEC 68-2-20 Test Ta method 1
Temperature Range -40°C ∼85°C
Relative Humidity 85%(at 40°C) IEC 68-2-3 Test Ca
Mass Approx. 1.5g

Safety approvals

Safety approval UL&CUR CQC
Load 30A,40A/277VDC,  30A,40A/277VDC,

 