N4099, 1-10A signal relay

 

Current: 1A,2A,3A,5A,6A,10A

Contact Form: 2A,2B,2C

DC: 3v-48v

 

>Model:N4099)JZC-7F)

10A DC48V 2A(DPSTNO)        6Pins PCB relay 

10A DC24V  2B(DPSTNC)        6Pins  PCB relay

10A DC12V   2C(DPDT)              8Pins PCB relay

>Application:

Automatic equipment relay;ommunications-equipment relay;

Radio remote control equipment relay;Sound control toy relay;

>Size:22*16.5*16.5MM;

>Contact arrangement:

2A(DPSTNO)        6Pins

2B(DPSTNC)         6Pins

2C(DPDT)              8Pins

Max.switching current:10A;

Max.switching Voltage:50VDC,380VAC;

Max.switching power:90W,850VA;

Contact Loading:

1A,2A,3A/277VAC,30VDC;

0.6W:3A,5A,10A/277VAC,6A/125VAC;

>Voltage available:3V,6V,9V,12V,24V,48V;

Product Detail

N4099, 1A 2A 3A 5A 6A,10A, signal pcb relay

 

Features

• Small size, light weight, Low price.

• Sensitive operation, good synchronism.

• Low coil power consumption.

• PC board mounting.

• Suitable for electrical application, telecommunication, automatic control, wireless radio remote controland sound controltoy application.

 

Ordering information

N4099      12D       E
    1                 2           3
1. Part number  N4099(JZC-7F)
2. Coil rated voltage(V)  DC:3,6,9,12,24,48
3. Enclosure  E: Sealed type                              NIL:Dust cover

 

Contact data

Contact Arrangement 2A (DPSTNO);           2B (DPSTNC);         2C (DPDT(B-M))
Contact Material AgCdO (Au clad);          AgSnO2 (Au clad);           AgNi (Au clad)
Contact Rating (resistive) 1A,2A,3A/277VAC,30VDC;
0.6W:3A,5A,10A/277VAC,30VDC   6A/125VAC
Max. Switching Power 0.45W:90W 850VA;        0.5W: 150w.950VA.          0.6W:300W 2770VA.
Max. Switching Voltage 50VDC            380VAC                                     Max. Switching Current:10A
Contact Resistance or         Voltage drop ≤50mΩ                                                              Item 4.12 of IEC 61810-7
Operational life Electrical 100,000 times                                                   Item 4.30 of IEC 61810-7
Mechanical 10,000,000 times                                              Item 4.31 of IEC 61810-7

CAUTION:、
1.For the intermediate current, it only applies to the room temperature.
2.For gold plated version, the min. Switching current and min.switching voltage is 50mA/6VDC; for non gold plated version (standard type),the min.
switching current and min. switching voltage is 100mA/6VDC.

 

Coil parameter

Dash numbers Coil voltage VDC Coil resistance ±Ω10% Pickup voltage
VDC(max)
(75% of rated
voltage )
Release voltage
VDC(min)
(10% of rated
voltage)
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
Rated Max.
003-450
006-450
009-450
012-450
024-450
048-450
3
6
9
12
24
48
3.9
7.8
11.7
15.6
31.2
62.4
20
80
180
320
1280
5120
2.25
4.50
6.75
9.00
18.0
36.0
0.3
0.6
0.9
1.2
2.4
4.8
0.45 ≤10 ≤5
003-500
006-500
009-500
012-500
024-500
048-500
3
6
9
12
24
48
3.9
7.8
11.7
15.6
31.2
62.4
18
72
162
288
1152
4608
2.25
4.50
6.75
9.00
18.0
36.0
0.3
0.6
0.9
1.2
2.4
4.8
0.5 ≤10 ≤5
003-600
006-600
009-600
012-600
024-600
048-600
3
6
9
12
24
48
3.9
7.8
11.7
15.6
31.2
62.4
15
60
135
240
960
3840
2.25
4.50
6.75
9.00
18.0
36.0
0.3
0.6
0.9
1.2
2.4
4.8
0.6 ≤10 ≤5

CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.

Operation condition

 Insulation Resistance  100MΩ min (at 500VDC)  Item 7 of IEC 60255-5
 Dielectric Strength
 Between contacts
 Between contact and coil
                                                                           50Hz 750V
 50Hz 1000V
                                                               Item 6 of IEC 60255-5
 Item 6 of IEC 60255-5
 Shock resistance  100m/s² 11ms  IEC 68-2-27 Test Ea
 Vibration resistance  10Hz~55Hz amplitude 1.5mm  IEC 68-2-6 Test Fc
 Terminals strength  10N  IEC 68-2-21 Test Ua1
 Solderability  235°C±2°C     3s±0.5s  IEC 68-2-20 Test Ta method 1
 Ambient Temperature  -40°C ~70°C
 Relative Humidity  85% (at 40°C )  IEC 68-2-3 Test Ca
 Mass  12g

 

Safety approvals

Safety approval UL&CUR CQC
Load 5A/277VAC 30VDC 6A/125VAC,30VDC 5A/277VAC
Inquiry