♦ Current:40A,60A,80A
♦ Contact Form: 1A,1B
♦ Coil: DC9v,12v,24v
>Model:JMX-94F
high power 80A SPDT lacthing relay
>Application:
Office equipment relay;Teaching audition equipment relay;
Armamentarium relay;Measuring instrument relay; Emulator relay;
Safety alarm relay;Street-light relay;Automatic control relay;
>Size:39*30*17.5MM;
>Contact arrangement:
1A(1H) SPSTNO;
1B(1D) SPSTNC;
>Max.switching current:80A;
>Max.switching Voltage:300VAC;
>Max.switching power:10000~20000VA;
>Contact Loading:80A/250VAC;60a/250vac;40A/250VAC;
>Voltage available:9V,12V,24V;
JMX-94f, 40/60/80A 1A/1B high power relay
Features
• Magnet latching relay.
• High sensitivity & reliability. • Well anti-shock and anti-vibration. • Heavy contact load. |
Ordering Information
JMX-94F A Z 60 DC12V D 1 2 3 4 5 6 |
|
1 Part number | JMX-94F |
2 Contact arrangement | A:1A B:1B |
3 Enclosure | S: Sealed type Z: Dust cover |
4 Contact current | 40:40A 60:60A 80:80A |
5 Coil rated voltage(V) | DC: 9,12, 24 |
6 Coil | NIL:Singal coil; D: Double coils |
Contact data
Contact Arrangement | 1A (SPSTNO) , 1B (SPSTNC) | |||
Contact Material | AgCdO | |||
Contact Rating(resistive) | 80A/250VAC | 60A/250VAC | 40A/250VAC | |
Max. Switching Power | 20000VA | 15000VA | 10000VA | |
Max. Switching Voltage | 300VAC Max. Switching Current:80A | |||
Contact Resistance & Voltage drop | 5m (at 1A/24VDC) Item 4.12 of IEC 61810-7 100mV (40A) Item 4.12 of IEC 61810-7 |
|||
Operational life | Mechanical | 10,000 times Item 4.30 of IEC 61810-7 | ||
Electrical | 1000,000 times Item 4.31 of IEC 61810-7 |
Coil Parameter
Dash numbers |
Coil rated voltage VDC |
Coil resistance 10% |
Switching voltage VDC (50%-70% of rated voltage) |
Pulse magnitude ms |
Coil power consumption W |
Operate Time ms |
Reset Time ms |
1 Coil | |||||||
009-1000 012-1000 024-1000 |
9 12 24 |
81 144 576 |
4.5~6.3 6.0~8.4 12.0~16.8 |
≥60 | 1 | ≤20 | ≤20 |
2 Coil | |||||||
009-2000 012-2000 024-2000 |
9 12 24 |
2 40.5 2 72 2 288 |
4.5~6.3 6.0~8.4 12.0~16.8 |
≥60 | 2×2 | ≤20 | ≤20 |
CAUTION:
1.When latching relays are installed in equipment, the latch and reset coil should not be powered simultaneously. Coil should not be pulsed
with less than thenominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these
conditions are not followed, it is possible for the relay to in be the magnetically neutral position .
2.Switching voltage is for test purpose only and are no to be used as design criteria.
Operation condition
Insulation Resistance | 1000MΩ min (at 500VDC) | Item 7 of IEC 60255-5 |
Dielectric Strength Between contacts Between contact and coil |
50Hz 1500V 50Hz 4000V |
Item 6 of IEC 60255-5 Item 6 of IEC 60255-5 |
Creepage distance | 8.4mm | Addenda B of IEC 60255-5 |
Shock resistance | Functional 100m/s2 ; Survival:1000 m/s2 11ms | IEC 68-2-27 Test Ea |
Vibration resistance | 10Hz~55Hz Double amplitude 1.5mm | IEC 68-2-6 Test Fc |
Terminals strength | 5N | IEC 68-2-21 Test Ua1 |
Solderability | 235°C±2°C 3s±0.5s | IEC 68-2-20 Test Ta method 1 |
Ambient Temperature | -25°C ~70°C | |
Relative Humidity | 85% (at 40°C ) |
IEC 68-2-3 Test Ca |
Mass | 40g |
Safety approvals
Safety approvals | CQC |
Load | 80A/220VAC |