JMX-94f, 40/60/80A high power relay

♦ Current:40A,60A,80A

Contact Form: 1A,1B

Coil: DC9v,12v,24v

 

>Model:JMX-94F

high power 80A SPDT lacthing relay

>Application:

Office equipment relay;Teaching audition equipment relay;

Armamentarium relay;Measuring instrument relay; Emulator relay;

Safety alarm relay;Street-light relay;Automatic control relay;

>Size:39*30*17.5MM;

>Contact arrangement:

1A(1H) SPSTNO;

1B(1D)  SPSTNC;

>Max.switching current:80A;

>Max.switching Voltage:300VAC;

>Max.switching power:10000~20000VA;

>Contact Loading:80A/250VAC;60a/250vac;40A/250VAC;

>Voltage available:9V,12V,24V;

Product Detail

JMX-94f, 40/60/80A  1A/1B high power relay

 

Features

•  Magnet latching relay.

•  High sensitivity & reliability.

•  Well anti-shock and anti-vibration.

•  Heavy contact load.

 

Ordering Information

JMX-94F      A      Z     60     DC12V       D
        1               2        3        4             5              6
1 Part number  JMX-94F
2 Contact arrangement  A:1A              B:1B
3 Enclosure  S: Sealed type            Z: Dust cover
4 Contact current  40:40A               60:60A               80:80A
5 Coil rated voltage(V)  DC: 9,12, 24
6 Coil  NIL:Singal coil;                D: Double coils

 

Contact data

Contact Arrangement 1A (SPSTNO) , 1B (SPSTNC)
Contact Material AgCdO
Contact Rating(resistive) 80A/250VAC 60A/250VAC 40A/250VAC
Max. Switching Power 20000VA 15000VA 10000VA
Max. Switching Voltage 300VAC                                                            Max. Switching Current:80A
Contact Resistance &   Voltage drop 5m (at 1A/24VDC)                                           Item 4.12 of IEC 61810-7
100mV (40A)                                                    Item 4.12 of IEC 61810-7
Operational life Mechanical 10,000 times                                                    Item 4.30 of IEC 61810-7
Electrical 1000,000 times                                                Item 4.31 of IEC 61810-7

Coil Parameter

Dash
numbers
Coil rated
voltage
VDC
Coil
resistance
10%
Switching
voltage VDC
(50%-70% of
rated voltage)
Pulse
magnitude
ms
Coil power
consumption
W
Operate
Time
ms
Reset
Time
ms
1 Coil
009-1000
012-1000
024-1000
9
12
24
81
144
576
4.5~6.3
6.0~8.4
12.0~16.8
≥60 1 ≤20 ≤20
2 Coil
009-2000
012-2000
024-2000
9
12
24
2 40.5
2 72
2 288
4.5~6.3
6.0~8.4
12.0~16.8
≥60 2×2 ≤20 ≤20

CAUTION:
1.When latching relays are installed in equipment, the latch and reset coil should not be powered simultaneously. Coil should not be pulsed
with less than thenominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these
conditions are not followed, it is possible for the relay to in be the magnetically neutral position .

2.Switching voltage is for test purpose only and are no to be used as design criteria.

 

Operation condition

 Insulation Resistance  1000MΩ min (at 500VDC)  Item 7 of IEC 60255-5
 Dielectric Strength
 Between contacts
 Between contact and coil
                                                           50Hz 1500V
 50Hz 4000V
                                                     Item 6 of IEC 60255-5
 Item 6 of IEC 60255-5
 Creepage distance  8.4mm  Addenda B of IEC 60255-5
 Shock resistance  Functional 100m/s2 ;                           Survival:1000 m/s2  11ms  IEC 68-2-27 Test Ea
 Vibration resistance  10Hz~55Hz                                       Double amplitude 1.5mm  IEC 68-2-6 Test Fc
 Terminals strength  5N  IEC 68-2-21 Test Ua1
 Solderability  235°C±2°C    3s±0.5s  IEC 68-2-20 Test Ta method 1
 Ambient Temperature  -25°C ~70°C
 Relative Humidity  85% (at 40°C )
 IEC 68-2-3 Test Ca
 Mass  40g

 

Safety approvals

Safety approvals CQC
Load 80A/220VAC

 

Inquiry