PL
Modelo: PL
Forma 2C DPDT 10Pins lacthing Relay
Función de funcionamiento: PL 1 bobina lacthing;
Tamaño: 14 * 9 * 5m m;
Uso: relais del equipo de oficina; Equipo de enseñanza audición relé; Relé armamentarium;
Relé del instrumento de medición; Relé de emulación; Relé de alarma de seguridad; Relé del detector;
Corriente de Max. switching: 2A;
Voltaje de Max. switching: 220VDC, 250VAC;
Energía de Max. switching: 60W; 62.5 va;
Arreglo del contacto: 2C (2Z) DPDT (B-M);
Cargamento del contacto: 1A, 2A/30VDC; 0.5 A/125VAC;
Voltaje disponible: 5V, 12V, 24V;
DPDT 2A 10pins lacthing Relay-PL
Features |
• DIL Pitch Terminals .High Sensitivity :0.14W or 0.10W Nominal Power • Conforms to FCC Part 68 1.5kV Surge and Dielectric 1000VAC • Monostable or bistable relays Single and double Coil magnet latching Type available • Application for Telecommunication Equipment,Office Equipment,Security Alarm Systems, Measuring instruments, Medical Monitoring Equipment,Audio Visual Equipment, Flight Simulator,Sensor Control |
Ordering Information | |
P L 12 W 1 2 3 4 |
|
1. Part number | P |
2. Operating function | NIL: Single Side Stable L:1 Coil Latching; K:2 Coil Latching |
3. Coil rated voltage(V) | DC:3,4.5,5,6,9,12,24 |
4. Contact material | NIL: AgPd W: AgNi |
Contact Data | ||
Contact Arrangement | 2C DPDT(B-M) (Bifurcated Crossbar) | |
Contact Material | AgPd(Gold clad ) AgNi(Gold clad) | |
Contact Rating (resistive) | 1A,2A/30VDC; 0.5A/125VAC | |
Max. Switching Power | 60W 62.5VA Min. Switching load 0.01mA/10mV Reference Value | |
Max. Switching Voltage | 220VDC 250VAC Max. Swit ching Curr ent:2A | |
Contact Resistance or Voltage drop |
≤50mΩ Item 4.12 of IEC 61810-7 | |
Operation life | Electrical | 1A/30VDC 2 105 0.5A/125VAC 1 105 Ag Ni 1 105 Item 4.30 of IEC 61810-7 |
Mechanical | 100,000,000 Item 4.31 of IEC 61810-7 |
CAUTION:
Relays previously tested or used above 10mA resistive at 6V maximum DC or peak AC open circuit are not recommended for subsequent use in low level applications.
Coil Parameter | |||||||||
Dash numbers | Coil voltage VDC |
Coil resistance 10% |
Pick up voltage VDC(max) (75%of rated voltage ) |
Release voltage VDC(min) (10% of rated voltage) |
Coil power W | Operate Time ms | Release /Reset Time ms |
||
Rated | Max. | ||||||||
P-003 P-004 P-005 P-006 P-009 P-012 P-024 |
3 4.5 5 6 9 12 24 |
7.5 11.25 12.5 15.0 22.5 30.0 48.0 |
64.3 144.6 178 257 579 1028 2880 |
2.25 3.38 3.75 4.50 6.75 9.00 18.0 |
0.3 0.45 0.5 0.6 0.9 1.2 2.4 |
0.14 0.14 0.14 0.14 0.14 0.14 0.20 |
Approx.2 | Approx.1 | |
1 Coil Latching | Reset(Max) | Reset | |||||||
PL-003 PL-004 PL-005 PL-006 PL-009 PL-012 PL-024 |
3 4.5 5 6 9 12 24 |
8.7 13.0 14.5 17.4 26.1 34.8 57.6 |
90 202.5 250 360 810 1440 3840 |
2.25 3.38 3.75 4.50 6.75 9.00 18.0 |
-2.25 -3.38 -3.75 -4.50 -6.75 -9.00 -18.0 |
0.10 0.10 0.10 0.10 0.10 0.10 0.15 |
Approx.2 | Approx.1 | |
2 Coil Latching | Set Coil | Reset Coil | Reset(Max) | Reset | |||||
PK-003 PK-004 PK-005 PK-006 PK-009 PK-012 PK-024 |
3 4.5 5 6 9 12 24 |
6 9 10 12 18 24 36 |
45 101 125 180 405 720 1920 |
45 101 125 180 405 720 1920 |
2.25 3.38 3.75 4.50 6.75 9.00 18.0 |
2.25 3.38 3.75 4.50 6.75 9.00 18.0 |
0.20 0.20 0.20 0.20 0.20 0.20 0.30 |
Approx.2 | Approx.1 |
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release(reset) voltage are for test purposes only and are not to be used as design criteria.
3.When latching relays are installed in equipment, the latch and reset coil should not be powered simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to be in the magne-tically neutral position .
Characteristics | ||
Electrostatic capacitance | ||
Between open Contacts | Approx.0.4pF | Item 4.41 of IEC 61810-7 |
Between coil & Contacts | Approx.0.9pF | Item 4.41 of IEC 61810-7 |
Between Contact Poles | Approx.0.2pF | Item 4.41 of IEC 61810-7 |
Insulation Resistance | 1000M min (at 500VDC) | Item 7 of IEC 60255-5 |
Dielectric Strength | ||
Between open Contacts Between coil & Contacts Between Contact Poles |
1000VAC 1min 1000VAC 1min 1000VAC 1min |
Item 6 of IEC 60255-5 Item 6 of IEC 60255-5 Item 6 of IEC 60255-5 |
Surge Withstand Voltage | ||
Between open Contacts Between coil & Contacts Between Contact Poles |
1500V 1500V 2500V |
FCC 68 FCC 68 FCC 68 |
Shock resistance | Functional:500m/s2 11ms; Survival:1000 m/s2 6ms |
IEC 68-2-27 Test Ea |
Vibration resistance | 10Hz~55Hz Double amplitude Functional 3mm Survival:5mm |
IEC 68-2-6 Test Fc |
Terminals strength | 5N | IEC 68-2-21 Test Ua1 |
Solderability | 235°C±2°C 3s°C±0.5s°C | IEC 68-2-20 Test Ta method 1 |
Temperature Range | -40°C ~70°C (-40°C ~158°C ) | |
Mass | Approx. 1.5g |
Safety approvals | ||
Safety approval | UL&CUR | T U V |
Load | 1A,2A/30VDC, 0.5A/125VAC | 1A/30VDC, 0.5A/125VAC |